MoniRAD® Area Measurement

Features

  • Enviromental radioactivity monitoring
  • Probes:  Geiger Mueller and Neutron
  • Output signal for visual and audible alarms
  • Real-Time data acquisition and control
  • Web and Stand-Alone  Interface
  • On board and remote datalog
  • Daily, Montly, Yearly and custom Report in PDF or Excel format.
  • Optional:
  • PLC output command for HVAC system
  • Monirad® Air Sampling Integration
  • Tablet and Smartphone user interface

Description

MoniRAD® Area Measure is the brain of the entire control system, on the Real-Time target allows to monitor constantly the radioactivity levels in the environment and generates an signal alarm when the radioactivity value exceeds the established threshold.

MoniRAD® Area Measure allow to drive different systems such as solenoid valve,  automatic doors, led tower alarm, etc,  via digital/analog output .

The system was developed for fast event response thanks to dedicated I/O devices that directly transfer the data to the control software running on the Real-Time system. The measure data are storage directly on the Real-Time target and are  programmatically sended to the Server.

 If a warning or a danger condition occurs in the environment, the MoniRAD®  update the GUI and sends the alarm by email or by other ways to be decided.

The MoniRAD® Area Measure software  has a multi-platform  Human User Interface (HMI) as Desktop PC, Laptop, Touch Panel.

Many communication protocols are available to connect the system with HMI software.

Itel telecomunicazioni srl will provide for installation, configuration and start-up of MoniRAD® system and will be able to interface it with the other control system such as HVAC control system.

 

EMITTERS

Gamma

DETECTOR

Energy Compensated Geiger Mueller

SENSITIVITY

0.74 c/s for μSv/h (137Cs).

MEASUREMENT RANGE

0.1 μSv/h to 10 Sv/h

(10 μrem/h to 1000 rem/h)

BACKGROUND

Ambient <0.1 μGy/h (10 μR/h), 0.10 c/s

MAXIMUM INTEGRATED DOSE

500 Sv.

COMUNICATION PROTOCOL

RS-485

CONNECTIVITY

Multiprobe

 

EMITTERS

Neutrons

DETECTOR

BF3-tube

ENERGY RANGE

50meV to 19 MeV

TIPICAL NEUTRON RESPONSE

1cps at 1.8 10 μSv/h

BACKGROUND

0.001 cps

GAMMA REJECTION

10-5 at 1 Sv/h

COMUNICATION PROTOCOL

RS-485

CONNECTIVITY

Multiprobe

 

Condividi o segnala questo articolo

In Evidenza

Fiere e Congressi

ASTRO 2019

ITEL/Linearbeam parteciperà come espositore al congresso annuale della American Society for Radiation Oncology (ASTRO 2019) che si terrà a Chicago, IL (USA) dal 15 al 18 Settembre 2019. Vieni a trovarci allo stand n° 843 per scoprire le nostre novità sulla protonterapia!

 


EANM 2019

ITEL parteciperà come espositore al Congresso Annuale dell'Associazione Europea di Medicina Nucleare (EANM'19) che si terrà a Barcellona (Spagna) dal 12 al 16 Ottobre 2019. Vieni a trovarci allo stand n°44!

 


Arab Health 2020

ITEL parteciperà come espositore all’evento “Arab Health 2020” che si terrà a Dubai dal 27 al 30 Gennaio 2020. Vieni a trovarci al nostro stand J50 nel padiglione S1!